Each System 4100 unit is wired in parallel from a central power supply using 16 AWG wire as the bus wire, with two pair telephone wire pigtails spliced in at each unit location. Each two-pair telephone wire pigtail should be terminated with an RJ-11 plug for connection to the unit. Connect the two pair telephone wire to pins 3 and 4 on the RJ-11 plug. The power supply is the only component of the system that needs to be plugged into a 110V/220V outlet. (See Hardwire Instructions)
Following are instructions for the installation of each wall mount System 4100 unit. You may contact our Customer Service Department at 1-800-899-4741 if you have any questions.
 |
1. |
Mark eight bracket screw holes. The edges of the opening should be a minimum of ¾ in. from any stud. |
 |
2. |
.Mark four corners of hole to be cut. This hole should be 7 in. by 7 in. |
 |
3. |
Draw outer lines of hole to be cut. |
 |
4. |
Cut hole. |
 |
5. |
Drill holes. |
 |
6. |
Insert bracket front into hole. |
 |
7. |
Insert bracket back into hole. |
 |
8. |
Secure bracket front to bracket back using the four long screws provided. |
 |
9. |
Connect wire to RJ-ll port and insert unit into bracket. |
 |
10. |
Secure outer plate with four short screws provided. | |